CIRCUIT BREAKER
The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and
voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized
up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal
options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher
interrupting capacities of up to 10,000 amps. Thermoset glass filled polyester half shell construction provides
for increased mechanical and electrical strength. The wiping contacts mechanical linkage, with two step
actuation, cleans contacts providing high, positive contact pressure and longer contact life. Available with
American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. The optional mid-trip
handle style actuator allows a visual indication of electrical overload with or without alarm feature.
Resources:
Configure a Complete Part
Download CAD & Sales Drawing
Product Highlights:
•ꢀ ExtensiveꢀlistꢀofꢀAgencyꢀApprovals
Typical Applications:
•ꢀ Marine
•ꢀ AvailableꢀwithꢀStandardꢀorꢀMetricꢀStudꢀterminals,ꢀꢀ •ꢀ Telecomꢀ/ꢀDatacom
ꢀ orꢀSaddleꢀClampꢀscrewꢀterminals
•ꢀ Military
•ꢀ Optionalꢀmid-tripꢀhandleꢀstyleꢀactuator
•ꢀ RenewableꢀEnergy
•ꢀ Uniqueꢀarcꢀchuteꢀdesignꢀwhichꢀallowsꢀforꢀhigherꢀꢀ
•ꢀ Generatorsꢀ&ꢀWelders
ꢀ interruptingꢀcapacitiesꢀofꢀupꢀtoꢀ10,000ꢀampsꢀ
•ꢀ ExclusiveꢀRockerguardꢀandꢀPush-To-Resetꢀbezel
•ꢀ Availableꢀwithꢀnewꢀsolidꢀcolorꢀandꢀtwo-colorꢀVisi-ꢀ
ꢀ rocker®ꢀactuators
•ꢀ Newꢀthermosetꢀglassꢀfilledꢀpolyesterꢀhalfꢀshellꢀꢀ
ꢀ construction
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
C-Series Circuit Breaker – General Specifications
2
Electrical
Maximum Voltage
Mechanical
Endurance
AC, 480 WYE/277 VAC, 50/60 Hz
(see Table A.)
UL489: AC,240 VAC. (See Table D),
50/60 Hz, 125 VDC
Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00, 2.50,
5.00, 7.50, 10.0, 15.0, 25.0, 30.0,
35.0, 40.0, 50.0, 60.0, 70.0, 80.0,
90.0 and 100 amps. Other ratings
available, see Ordering Scheme.
10,000 ON-OFF operations @ 6 per
minute; with rated current &
voltage.
Trip Free
All C-Series circuit breakers will trip
on overload, even when actuator is
forcibly held in the ON position.
The operating actuator moves
positively to the OFF position when
an overload causes the breaker to
trip. With mid-trip, handle moves to
the mid position on electrical trip of
the circuit breaker. With mid trip
handle with alarm switch, handle
moves to the mid position and the
alarm switch actuates when the
circuit breaker is electrically
tripped.
Current Rating
Trip Indication
Standard Voltage Coils DC - 6V, 12V; AC - 120V; other
ratings available, see Ordering
Scheme.
Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux.
Switch 1.0A, 65 VDC. 0.5A,
80VDC,1/4 HP, 125VAC,VDE & TUV
1.0 125 VAC.
Insulation Resistance
Dielectric Strength
Minimum of 100 Megohms at 500
VDC.
Physical
UL, CSA: 1960 V 50/60 Hz for one
minute between all electrically
isolated terminals. C-Series Circuit
Breakers comply with the 8mm
spacing and 3750V 50/60 Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, between
adjacent poles and from main
circuits to auxiliary circuits per
Publications EN 60950 and
VDE 0805.
Number of Poles
1-6 poles ≤ 50A; 1-4 poles @ 51-
70A; 1-2 poles 71-100A. UL489
Handle: 1 pole ≤ 100A, 2 pole ≤
50A; Rocker: 1 pole ≤ 100A.
Internal Circuit Config. Series (with or without auxiliary
switch, mid trip & mid trip with
alarm switch) Shunt & Relay with
current or voltage trip coils, Dual
Coil, Switch Only (with or without
aux. switch). UL489: Series (with or
without auxiliary switch, mid-trip &
midtrip with alarm switch).
Resistance, Impedance Values from Line to Load Terminal -
based on Series Trip Circuit
Weight
Standard Colors
Approx.112 grams/pole ( 3.95 oz).
Housing: Black
RESISTANCE, IMPEDANCE VALUES
Breaker.
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
Environmental
1000
CURRENT
(AMPS)
TOLERANCE
(%)
Designed and tested in accordance with requirements of
100
10
specification MIL-PRF-55629 & MIL-STD-202 as follows:
0.10 - 5.0
5.1 - 20.0
20.1 - 50.0
15
25
35
Shock
Withstands 100 Gs, 6ms sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultrashort curves
tested @ 90% of rated current.
Withstands 0.060” excursion from
10-55 Hz & 10 Gs 55-500 Hz, @
rated current per Method 204C,
Test Cond. A. Instantaneous &
ultrashort curves tested @ 90% of
rated current.
Method 106D, i.e., ten 24-hour
cycles @ +25°C to +65°C,
80-98% RH.
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (five
cycles @ -55°C to +25°C to +85°C
to +25°C).
O
H
M
S
1
0.1
0.01
Vibration
0.001
0.01
0.1
1
10
100
AMPERE RATING
Pulse Tolerance Curves
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
50 Hz 1/2 Cycle
Moisture Resistance
Inrush Pulse Tolerance
I
I
r
r
Time Delay Curves
Time Delay Curves
42, 44
& 46
22x
10x
42, 44
& 46
(50 Amps Max.)
(50 Amps Max.)
25x
12x
Time Delay Curves
Time Delay Curves
22, 24 (100 Amps Max.)
26 (70 Amps Max.)
22, 24 (100 Amps Max.)
26 (70 Amps Max.)
Salt Spray
t
t
10.0
20.0
5.0
8.33
16.67
4.165
Time in
Milliseconds
Thermal Shock
Operating Temperature -40°C to +85°C
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
3
C-Series Circuit Breaker – General Specifications
Electrical Tables
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a component supplementary protector
C-SERIES TABLE A: Component Supplementary Protectors
Short Circuit
Voltage
Current Rating
Application Codes
Capacity (Amps)
UL / CSA
Circuit
Configuration
Full General
Construction Notes
Max.
With Without
Backup Backup
Frequency Phase Load
Amps
Purpose
Amps
UL
CSA
Rating
Fuse
---
---
Fuse
5,000
5,000
32
48
DC
DC
---
---
0.02 - 100
110 - 150
0.02 - 70
-
0.02 - 70
---
0.02 - 70
---
0.02 - 50
0.02 - 50
0.02 - 50
---
---
---
71 - 100
---
71 - 100
---
71 - 100
---
---
---
---
---
---
---
---
TC1, OL1, U2
TC1, OL1, U2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
65
DC
---
---
5,000
7,500
80
DC
---
---
10,000
Must have Agency "L"
125
125/250
250
DC
DC
DC
---
---
---
---
---
---
5,000
5,000
5,000
3,000
5,000
Must have Agency "L"
Must have Agency "L"
---
TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L". 250 volts requires 2 pole
---
---
TC1, OL1, U2
TC1, OL1, U2
Per pole rating
Must have Agency "L"
Must have Agency "L"
125
150
50 / 60
DC
1
0.02 - 100
---
---
---
TC1, 2, OL1, U1 TC1, 2, OL1, U1
80 - 100
101 - 175
---
5,000
TC1, 2, OL0, U3
TC1, OL1, U2
---
Must have Agency "L" parallel pole
---
2 or 3 poles breaking single phase
2 or 3 poles breaking single phase
Series
0.02 - 100
0.02 - 50
51 - 100
0.02 - 100
0.02 - 50
0.02 - 100
51 - 70
---
3,500
3,000
1,000
5,000
3,500
5,000
---
3,000
---
5,000
--
TC1, OL1, U2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U2 TC1, 2, OL1, U2 2 or 3 poles breaking single phase. Agency "L"
125/250
250
50 / 60
50 / 60
1
---
---
---
---
TC1, 2, OL1, U2 TC1, 2, OL1, U2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, U2 TC1, 2, OL0, U2
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
Per pole rating
Must have Agency "L"
1
3
5,000
---
5,000
---
---
---
0.02 - 100
0.02 - 70
---
0.02 - 50
0.02 - 30
---
---
0.02 - 90
---
3 poles breaking 3 phase
Must have Agency "L"
277
50 / 60
50 / 60
1
3
5,000
---
---
3 poles breaking 3 phase
480/277
5,000
5,000
--
--
---
0.02 - 30
---
---
2 poles breaking 1 phase
480
50 / 60
1
---
---
80
125
DC
50 / 60
---
1
0.02 - 50
0.02 - 50
---
---
---
---
7,500
3,000
3,500
3,000
3,500
3,000
---
---
7,500
---
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
Per pole rating
2 or 3 poles breaking single phase
2 or 3 poles breaking single phase
125/250
250
50 / 60
50 / 60
1
1
3
0.02 - 50
---
---
TC1, 2, OL1, U1 TC1, 2, OL1, U1
Dual Coil
---
---
TC1, OL1, U2
TC1, OL0, U2
TC1, OL1, U2
TC1, OL0, U2
---
0.02 - 50
---
Per pole rating
5,000
5,000
---
5,000
5,000
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
---
277
80
277
250
50 / 60
DC
50 / 60
50 / 60
1
---
1
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 30
---
---
---
---
---
---
31 - 50
---
31 - 50
---
---
---
3 poles breaking 3 phase
---
---
3
---
3 poles breaking 3 phase
3 poles breaking 3 phase
Shunt
Relay
480/277
480
50 / 60
50 / 60
3
1
5,000
5,000
---
---
---
0.02 - 30
---
2 poles breaking 1 phase
---
---
---
80
277
250
DC
50 / 60
50 / 60
---
1
3
0.02 - 50
0.02 - 50
0.02 - 50
71 - 100
---
---
5,000
5,000
7,500
---
---
3 poles breaking 3 phase
65
80
DC
DC
---
---
---
---
---
---
---
---
---
---
---
---
---
---
71 - 100
---
125
125/250
50 / 60
50 / 60
1
1
1
3
1
0.02 - 100
0.02 - 100
0.02 - 100
0.02 - 70
0.02 - 50
0.02 - 30
---
---
---
---
---
---
---
---
---
---
---
---
Switch Only
2 or 3 poles breaking single phase
---
---
---
250
277
50 / 60
50 / 60
50 / 60
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
31 - 50
3 poles breaking 3 phase
---
480/277
3
Notes:
1.
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less
rating and not to exceed 175 for 51 through 100 Amp rating
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
C-Series Circuit Breaker – General Specifications
Electrical Tables
Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller.
Notes:
C-SERIES TABLE B: Manual Motor Controllers
1. Requires branch circuit backup with a UL Listed
Type K5 or RK5 fuse rated 15A Minimum and no
Voltage
Frequency
50 / 60
Current Rating
Full Load Amps
0.02 - 50
Horsepower Ratings
Circuit
Configuration
more than 4 times full load amps not to exceed
125A for 50 Amp or less rating and not to exceed
175A for 51 through 100A rating.
Max. Rating
120 1
Phase
Max. HP
1
1
3
1
3
7 ꢀ
3
5
3
5
2. UL Recognized and CSA Certified at 480V refers
to 3 and 4 pole versions used in a 3Ø, WYE
connected circuit or a 2 pole version with 2 poles
breaking 1Ø and backed up with a series fusing as
stated in note 1.
Series,
Shunt &
Relay Switch
Only
0.02 - 20
0.02 - 20
0.02 - 20
0.02 - 20
250 1
50 / 60
277 1
480 2
50 / 60
50 / 60
*
Shunt and Relay Trip - Voltage Coil
Construction not current coils
Table C: Lists UL Recognized, CSA Accepted, VDE and TUV Certified configurations and performance capabilities as a
Component Supplementary Protector.
C-SERIES TABLE C: Component Supplementary Protectors
Voltage
Current Rating
Short Circuit Capacity (Amps)
UL / CSA VDE
TUV
Application
Codes
Circuit
Configuration
Full General
(Inc)
(Icn)
(Inc)
(Icn)
Construction Notes
Max.
Rating
With Without
Backup Backup
Frequency Phase Load Purpose
With Without With Without
Backup Backup Backup Backup
Amps
Amps 1
UL / CSA
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
---
---
---
---
0.10 - 70
71 - 100 71 - 100
1 - 50
0.10 - 50
0.10 - 70
0.10 - 100
0.10 - 90
---
---
---
---
7,500
10,000
5,000
---
---
---
---
5,000 5,000 1,500 TC1,2,OL1,U1
---
80
DC
Agency F, H, J or R
Agency J or R
2P, Agency J or R
---
5,000
---
---
---
---
---
5,000 TC1,2,OL0,U1
5,000 TC1,2,OL1,U1
5,000
125
DC
DC
---
Series
3,000 1,500 3,000 1,500
---
---
3,000 1,500
5,000 2,500
---
250
1
3
3
---
---
5,000
TC1,2,OL1,U1
50 / 60
---
---
Agency J or R
5,000 5,000
Rocker
415
50 / 60
0.10 - 30
---
---
5,000 2
---
---
3,000 1,500 TC1,2,OL1,C1
Handle, Agency F, H, J or R
80
250
80
DC
50 / 60
DC
---
1 & 3
---
7,500
5,000 3,000
7,500 ---
5,000
---
Dual Coil
0.10 - 30
0.10 - 70
1,500
1,500 TC1,2,OL1,U1
3,000
---
---
---
---
---
5,000 5,000 1,500 TC1,2,OL1,U1
---
250
50 / 60
1 & 3 0.10 - 70
5,000 3,000 1,500 3,000 1,500 TC1,2,OL1,U1
3,000 1,500
Shunt
Rocker
415
50 / 60
3
0.10 - 30
---
5,000 2
---
3,000 1,500 TC1,2,OL1,C1
Handle, Agency F, H, J or R
5,000 2,500
Notes:
1.
2.
General Purpose ratings for UL/CSA only.
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less
rating and not to exceed 175 for 51 through 100 Amp rating.
Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case
Circuit Breaker.
C-SERIES TABLE D: UL489 Listed Branch Circuit Breakers
Voltage
Current Rating Interrupting Capacity (Amps)
Circuit
Configuration
Construction Notes
Max. Rating Frequency Phase Full Load Amps
Without Backup Fuse
50,000 1
10,000
10,000
10,000
5,000
5,000
10,000
5,000
5,000
10,000 1
5,000
10,000
10,000
Limited to 2 Poles Max from 71 - 100 Amps
0.10 - 100
80
DC
---
2 Poles - Parallel Poles
3 Poles - Parallel Poles
101 - 150
151 - 250
0.10 - 100
0.10 - 50
0.10 - 50
51 - 70
1 - 3 Poles
125
125 / 250
DC
DC
---
---
1 or 2 Poles (2 poles required for 250 Volts)
Series
1 - 3 Poles
120
120 / 240
240
50 / 60
50 / 60
50 / 60
1
1
1
2 or 3 Poles (1 pole of a 3 pole unit is neutral)
0.10 - 50
1 Pole
2 Poles
0.10 - 30
0.10 - 20
0.10 - 20
Notes:
Special catalog
1-2 Poles
277
120
50 / 60
50 / 60
1
1
1
number required.
Consult factory.
---
Dual Coil
0.10 - 30
10,000
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
5
C-Series Circuit Breaker – General Specifications
Electrical Tables
Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
C-SERIES TABLE E: UL1500 (Marine Ignition Protection)
Interrupting
Capacity (Amps)
Voltage
Current Rating
Application Codes
Circuit
Configuration
Construction
Notes
Max.
Rating
Full Load
Amps
Without
Backup Fuse
Frequency
Phase
---
UL
CSA
0.02 - 100
101 - 150
0.02 - 100
0.02 - 70
0.02 - 70
71 - 100
48
DC
5,000
TC1, 2, OL1, U1
TC1, 2, OL1, U1
---
65
80
DC
DC
---
---
1,500
1,500
5,000
1,500
TC1, 2, OL0, U1
TC1, 2, OL1, U1
TC1, 2, OL0, U1
TC1, 2, OL1, U1
---
---
Series
125
50 / 60
1
TC1, 2, OL1, U1
TC1, 2, OL1, U1
---
---
0.02 - 70
50 / 60
1
250
1,500
TC1, 2, OL1, U1
TC1, 2, OL1, U1
2 Poles Breaking
Single Phase
71 - 100
Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A.
C-SERIES TABLE F: PARALLEL POLE CONSTRUCTION
UL489A Listed for Communications Equipment
Voltage
Max. Rating
80
Current Rating
Interrupting Capacity (Amps)
Without Backup Fuse
Circuit
Configuration
Frequency
DC
General Purpose Amps
Series
100 - 250
10,000
Agency Certifications
Component Supplementary
Protector under Class 3215 30,
FIle 047848 0 000 CSA
UL Recognized
UL Standard 1077
CSA Accepted
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
Standard C22.2 No. 235
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
Circuit Breaker Model Case
(Class 1432 01, File 093910),
CSA Standard C22.2 No. 5.1 - M
UL Standard 508
UL Standard 1500
CSA Certified
TUV Certified
VDE Certified
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
EN60934, under License No.
R72040875
UL Listed
UL Standard 489
Circuit Breakers, Molded Case,
(Guide DIVQ, File E129899)
EN60934, VDE 0642 under File
No. 10537
Communications Equipment
UL Standard 489A
(Guide CCN/DITT, File E189195)
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
C-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme
C A 3 B 0 10 450 1 2 1 C
8
9
10
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Mounting
Bezel/Barrier
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
1 SERIES
C
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
1
2 ACTUATOR
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
2
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
9
660 60.000
9
670 70.000
3
4
4
4,5
4 CIRCUIT
F
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
9
680 80.000
3
A
B
C
D
E
Switch Only (No Coil)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
G
H
9
685 85.000
9
690 90.000
9
695 95.000
4
4
4,5
9
K
810 100.00
7
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
5 AUXILIARY / ALARM SWITCH
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
0
2
3
4
without Aux Switch
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
J06
6 AC
15
8 TERMINAL
10
12
13,15
15
14
11,15
1
2
3
4
5
Stud 10-32
Screw 10-32
Stud 1/4-20
Stud M5 x 0.8
Screw M5 x 0.8
6
Stud M6
11
12
11
11
7
0.250 Double Click Connect
7/16” Clip Terminal
Plug-In Stud
6 FREQUENCY & DELAY
9
A
C
3
7
03 DC 50/60Hz, Switch Only
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
10 DC Instantaneous
5/16” Clip Terminal
11 DC Ultra Short
12 DC Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
14 DC Medium
16 DC Long
16
9 ACTUATOR COLOR & LEGEND
8
8
8
8
42 50/60Hz Short, High-inrush
Actuator Color
White
I-O
A
C
F
H
K
M
P
ON-OFF
Dual
1
Legend Color
Black
7
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
B
D
G
J
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
Black
2
White
52 DC Short, High-inrush
Red
3
White
8
54 DC Medium, High-inrush
Green
4
White
56 DC Long, High-inrush
Blue
L
5
White
Notes:
Yellow
N
Q
S
U
6
Black
1
Actuator Code:
Gray
7
Black
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles
Orange
Black (short handle)
R
T
8
Black
17
9
White
5 pole - three handles at center poles
6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available
with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip
of the breaker. Available with circuit codes B & C.
Standard multipole units have all poles identical except when specifying auxiliary
switch and/or mixed poles. 4 pole max with VDE. 5th pole available as Series Trip with
Voltage Coil only.
Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D, F, H & K available up to 50 amps maximum Current Rating.
Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only, and up to 50 amps maximum.
Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100
are available up to two poles maximum.
10 MOUNTING / BARRIERS
MOUNTING STYLE
BARRIERS
VOLTAGE
Threaded Insert
1
6-32 x 0.195 inches
6-32 X 0.195 inches
6-32 X 0.195 inches
ISO M3 x 5mm
no
< 300
< 300
≥ 300
< 300
< 300
≥ 300
2
3
A
C
2
yes
yes
no
18
18
B
D
ISO M3 x 5mm
yes
yes
ISO M3 x 5mm
Front panel Snap-In, 1.00” [25.4mm] wide bezel
4
5
17
E
with Handleguard
no
< 300
11 AGENCY APPROVAL
C
D
E
H
I
UL Recognized, CSAAccepted
VDE Certified, UL Recognized, CSAAccepted
TUV Certified, UL Recognized, CSAAccepted
UL489 Construction: VDE Certified, UL Recognized, CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
CSAAccepted
UL489 Construction: UL Recognized, CSAAccepted
UL489 Construction: TUV Certified, UL Recognized, CSAAccepted
6
7
8
9
L
R
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.
12 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
16 No marking available. Consult factory. VDE/TUV Approval requires dual
(I-O, ON-OFF) or I-O markings on all handles.
17 Single pole only.
18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or
to be used in applications with a motor.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
7
C-Series Circuit Breaker - Handle UL489 & UL489A Listed / Parallel Pole – Ordering Scheme
C A 2 P 0 D4 820 3 2 1 M T
8
9
10
Mounting
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
5
8 TERMINAL
1 SERIES
3
6
A
1/4-20 threaded Stud
M6 threaded Stud
Plug-In Stud
C
3
2 ACTUATOR
A
S
T
Handle, one per pole
2
1
9 ACTUATOR COLOR
Mid-Trip Handle, one per pole
1
LEGEND
ON-OFF
Mid-Trip, one per pole & Alarm Switch
Dual
Legend Color
Black
White
Black
Red
Green
Blue
Yellow
Gray
Orange
B
D
G
J
1
2
3
4
5
6
7
8
4
3 POLES
White
1
2
3
One
White
Two
White
Three
L
White
N
Q
S
Black
Black
Black
4 CIRCUIT
P
Series Trip (parallel pole)
10 MOUNTING
5 AUXILIARY / ALARM SWITCH
Threaded Insert
0
2
3
4
without Aux Switch
6
7
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C
Term. (Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
1
2
6-32 x 0.195 inches
ISO M3 x 5mm
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
8
9
11 MAXIMUM APPLICATION RATING
80 DC
5
S.P.S.T., N.O., 0.110 Q.C
Term. (Gold Contacts)
M
6
12 AGENCY APPROVAL
6 FREQUENCY & DELAY
D1 DC Ultra Short
D2 DC Short
A
G
J
Without Approval
UL489 Listed
UL489A Listed, TUV Certified
UL489A Listed, VDE Certified
UL489A Listed
D4 DC Medium
D6 DC Long
K
T
7
UL489A Listed, TUV Certified
4
7 CURRENT RATING (AMPERES)
CODE AMPERES
Notes:
810 100.00
811 110.00
812 120.00
912 125.00
813 130.00
814 140.00
815 150.00
816 160.00
817 170.00
917 175.00
818 180.00
819 190.00
820 200.00
922 225.00
825 250.00
1
Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is
specified. When Actuator Code T is specified, handle moves to Mid Position and
Alarm Switch actuates only upon electrical trip of C/B. Code T is only available with
Circuit Code N.
2
3
Standard Handle colors are White, Black, Red & Yellow.
Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line
and Load Terminals. For Terminal Code A, Line and Load Terminals must be
connected to a copper bus bar having a minimum cross-section of 0.078 square
inches. Terminal Code A is not available on the single pole unit.
Ratings for 101 to 125 amps are available in 1-pole.
4
Ratings from 110 to 200 amps are available in 2-pole.
For ratings from 225-300 amps, specify 3-pole.
1 pole only available with terminal codes 3 and 6.
Agency codes K and 7 are not available with 1 pole.
5
6
Agency code J is only available with 1 pole.
Agency code G is only available in 2 and 3 pole.
Circuit P, ratings 101-150 amps (2 pole) and ratings 151-250 amps (3 pole).
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
C-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme
C A 3 B 0 14 450 1 2 1 K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
1 SERIES
C
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.00
1
2 ACTUATOR
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
2
3 POLES
One
1
2
Two
3
Three
4 CIRCUIT
Series Trip (Current)
B
3
5 AUXILIARY / ALARM SWITCH
0
2
3
4
without Aux Switch
6
8 TERMINAL
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
7
9
9
10
1
2
3
4
5
Stud 10-32
Screw 10-32
Stud 1/4-20
Stud M5 x 0.8
Screw M5 x 0.8
6
Stud M6
8
9
8
8
9
7/16” Clip Terminal
A
C
Plug-In Stud
5/16” Clip Terminal
8
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
26 50/60Hz Long
11
9 ACTUATOR COLOR & LEGEND
4
42 50/60Hz Short, High-inrush
Actuator Color
White
ON-OFF
Dual
Legend Color
Black
4
4
4
4
14 DC Medium
44 50/60Hz Medium, High-inrush
B
D
G
J
1
2
3
4
5
6
7
8
16 DC Long
46 50/60Hz Long, High-inrush
Black
White
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
52 DC Short, High-inrush
Red
White
54 DC Medium, High-inrush
Green
Blue
Yellow
Gray
White
4
56 DC Long, High-inrush
L
White
N
Q
S
Black
Black
Notes:
1
Actuator Code:
Orange
Black
A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units.
B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip
of the breaker.
Standard multipole units have all poles identical except when specifying auxiliary
switch and/or mixed poles.
2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating
code C) applications, have all poles identical except when specifying auxiliary /
alarm switch which is normally supplied in extreme right pole per figure B. Terminal
barriers are required on all multipole breakers.
10 MOUNTING / BARRIERS
MOUNTING STYLE
12
BARRIERS
Threaded Insert
2
1
2
6-32 x 0.195 inches
ISO M3 x 5mm
yes
yes
11 MAXIMUM APPLICATION RATING
B
C
D
K
F
125 DC
120/240 AC
240 AC
120 AC
277 AC
80 DC
Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd
pole has the same construction as poles 1 & 2.
On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme
right pole.
2
3
VDE approval on auxiliary switch codes 2, 3 & 4 only.
Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit,
only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC,
and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit
breaker, is supplied from factory with common terminal of auxiliary / alarm switch
connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated
120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common
terminal connected to breaker line terminal. Consult factory for special catalog
number.
M
11
12 AGENCY APPROVAL
A
F
G
J
without approvals
UL489 Listed, CSA Certified & VDE Certified
UL489 Listed & CSA Certified
UL489 Listed, CSA Certified & TUV Certified
4
5
Available up to 50 amps maximum.
Current ratings 71 - 100 with VDE approvals are available up to two poles
maximum.
6
7
8
9
Terminal Codes 9 & C are not VDE approved.
Terminal Code 1 available to 60 amps maximum.
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
Terminal Codes 3, 6 & 9 available to 100 amps maximum.
10 Terminal Code A available to 100 amps maximum.
11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles.
12 Barriers supplied on multi-pole units only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
9
C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
.960 [24.38]
.311 DIA [Ø7.90]
.558 [14.17]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Available on Series Trip and Switch Only Circuits when called for on multi-pole units.
Only one auxiliary switch is normally supplied, as viewed in mulit-pole identification scheme.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
4
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Schematic shown represents current trip circuits.
Available only as special catalog number.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
11
C-Series Circuit Breaker - Handle – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
C-Series Circuit Breaker - Handleguard – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
13
C-Series Circuit Breaker - Arc Chute Barrier UL Recognized/Listed – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
Only 1-pole and 3-pole configurations shown. Arc chute (without barrier) and arc chute
barrier also available for 2-pole construction.
2
3
Dimensions apply to all variations shown.
Notice that line and load terminal orientation for indicate on and indicate off rocker
circuit breakers are opposite.
4
Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For
other terminal configurations see circuit and terminal diagrams.
All dimensions are in inches [millimeters].
5
6
7
Tolerance ± .020 unless otherwise specified.
Must be ordered under a special catalog number.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
14
C-Series Circuit Breaker - Parallel Pole – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
15
C-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme
C M 3 B 0 10 450 1 0 1 C
8
9
10
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Legend
Plate
Mounting
Bezel/Barrier
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
9
1 SERIES
C
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
1
2 ACTUATOR
M
Sealed Toggle, one per pole
3 POLES
1
One
2
Two
3
Three
3
3
3,4
4 CIRCUIT
F
Relay Trip (current)
Relay Trip (voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
2
A
B
C
D
E
Switch Only (no coil)
G
9
Series Trip (current)
Series Trip (voltage)
Shunt Trip (current)
Shunt Trip (voltage)
H
660 60.000
9
670 70.000
9
3
3
3,4
680 80.000
K
9
685 85.000
9
690 90.000
9
695 95.000
9
810 100.00
5 AUXILIARY / ALARM SWITCH
0
2
3
4
without Aux Switch
7
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
J06
6 AC
6 FREQUENCY & DELAY
2
8 TERMINAL
03 DC 50/60Hz, Switch Only
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
9
11
6
1
2
3
4
5
Stud 10-32
6
Stud M6
10 DC Instantaneous
10
11
10
10
12
11
13
10
Screw 10-32
Stud 1/4-20
7
0.250 Double Click Connect
7/16” Clip Terminal
Plug-In Stud
11 DC Ultra Short
12 DC Short
9
A
C
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
Stud M5 x 0.8
14 DC Medium
16 DC Long
7
7
7
7
Screw M5 x 0.8
5/16” Clip Terminal
42 50/60Hz Short, High-inrush
6
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
9 LEGEND PLATE
No Legend
52 DC Short, High-inrush
7
0
54 DC Medium, High-inrush
56 DC Long, High-inrush
10 MOUNTING / BARRIERS
MOUNTING STYLE
Notes:
BARRIERS
no
1
Actuator Code M: Handle location as viewed from front of breaker:
2 pole - right pole 3 pole - center pole
1
Standard Hex Nut
Standard Hex Nut (multi-pole units only)
2
Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE.
For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current
Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select
Current Code 810.
A
yes
11 AGENCY APPROVAL
3
4
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only.
Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
C
I
L
UL Recognized & CSA Accepted
UL Recognized & CSA Accepted, UL1500 ignition protection
UL Recognized & CSA Accepted with listed construction
5
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only, and up to 50 amps maximum.
Consult factory for current ratings 71-100, in three pole units, available as special
catalog number only.
6
7
8
9
Terminal Code 1 available to 60 amps maximum.
10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum.
11 Terminal Codes 3, 6 & 9 available to 100 amps maximum.
12 Terminal Code 7 available to 25 amps maximum.
13 Terminal Code A available to 100 amps maximum.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
16
C-Series Circuit Breaker - Sealed Toggle – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
17
C-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme
14 450
C C 3 B 0
1 2 1 D
6
7
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
Frequency
& Delay
Current Rating
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
1 SERIES
C
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
1
2 ACTUATOR
Two Color Visi-Rocker
C
D
E
F
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate ON, no legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Indicate OFF, no legend
G
H
Push-To-Reset, Visi-Rocker
N
O
P
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Indicate OFF, no legend
9
660 60.000
9
Single color
670 70.000
9
J
K
L
Vertical legend
Horizontal legend
No legend
680 80.000
9
685 85.000
9
690 90.000
9
Push-To-Reset, Single color
695 95.000
9
R
U
V
Vertical legend
Horizontal legend
No legend
810 100.00
7
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
2
3 POLES
One
1
2
Two
3
Three
J06
6 AC
4
4
4,5
4,5
4 CIRCUIT
F
Relay Trip (Current)
3
8 TERMINAL
A
B
C
D
E
Switch Only (No Coil)
G
H
Relay Trip (Voltage)
10
12
13
1
2
3
4
5
Stud 10-32
6
Stud M6
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
11
12
11
11
Screw 10-32
Stud 1/4-20
7
0.250 Double Quick Connect
7/16” Clip Terminal
Plug-In Stud
4
4
9
A
C
K
14
Stud M5 x 0.8
Screw M5 x 0.8
5/16” Clip Terminal
6
5 AUXILIARY / ALARM SWITCH
16,17,18
9 ACTUATOR COLOR & LEGEND
Actuator or
0
2
3
4
without Aux Switch
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
Visi-Color Marking:
MarkingColor:
Single Color
Color:
White
Black
Red
I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker
A
C
F
H
K
M
P
R
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
6 FREQUENCY & DELAY
Green
Blue
Green
Blue
Yellow
Gray
Orange
03 DC 50/60Hz, Switch Only
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
L
7
10 DC Instantaneous
Yellow
Gray
Orange
N
Q
S
11 DC Ultra Short
12 DC Short
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
14 DC Medium
16 DC Long
8
8
8
8
8
8
42 50/60Hz Short, High-inrush
7
1
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
10 MOUNTING / BARRIERS
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
STANDARD ROCKER BEZEL
6-32 x 0.195 inches
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
BARRIERS
VOLTAGE
<300
52 DC Short, High-inrush
1
2
3
4
5
6
no
54 DC Medium, High-inrush
yes
yes
no
yes
yes
<300
19
19
56 DC Long, High-inrush
≥300
<300
Notes:
ISO M3 x 5mm
<300
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
ISO M3 x 5mm
≥300
Multi-pole breakers have all poles identical except when specifying Auxiliary switch
and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from
front panel: 2 pole – left pole; 3 pole – center pole.
ROCKERGUARD BEZEL
6-32 x 0.195 inches
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
ISO M3 x 5mm
ISO M3 x 5mm
A
C
E
G
J
no
<300
<300
≥300
<300
<300
≥300
3
Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to
30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D,F,H & K available up to 50 amps maximum Current Rating.
Consult factory for available Dual Coil options, as special catalog number is
required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously
on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip
instantaneously and are rated for intermittent duty only.
yes
yes
no
19
19
4
5
yes
yes
L
PUSH-TO-RESET BEZEL
6-32 x 0.195 inches
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
B
D
F
no
<300
<300
≥300
<300
<300
≥300
yes
yes
no
19
19
6
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxiliary
switch codes 2, 3 & 4 are VDE approved.
H
J
ISO M3 x 5mm
yes
yes
7
8
9
Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only, and up to 50 amps maximum.
Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are
available up to two poles maximum.
M
ISO M3 x 5mm
10 Terminal Code 1 available to 60 amps maximum.
11 AGENCY APPROVAL
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
C
D
E
H
I
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
14 Terminal Code A available to 100 amps maximum.
15 Terminal Codes 7, 9 & C are not VDE approved.
UL489 Construction: VDE Certified, UL Recognized & CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
16 Color shown is visi and legend with remainder of rocker black
17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered.
Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None
= no legend with actuator codes H, L, P, V. Rockerguard available with actuator
codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V.
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only
and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or
to be used in applications with a motor.
L
R
UL489 Construction: UL Recognized & CSA Accepted
UL489 Construction: TUV Certified, UL Recognized & CSA Accepted
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
18
C-Series Circuit Breaker - Rocker UL489A Listed / Parallel Pole – Ordering Scheme
C 1 2 P 0 D4 820 3 2 A M T
8
9
10
Mounting
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
3
8 TERMINAL
1 SERIES
3
6
A
Stud 1/4-20
Stud M6
Plug-In Stud
C
1
2 ACTUATOR
C
D
F
G
J
Curved Rocker, Two Color Visi, Indicate On, Vertical Legend
Curved Rocker, Two Color Visi, Indicate On, Horizontal Legend
Curved Rocker, Two Color Visi, Indicate Off, Vertical Legend
Curved Rocker, Two Color Visi, Indicate Off, Horizontal Legend
Curved Rocker, Single Color, Vertical Legend
9 ACTUATOR COLOR
LEGEND
ON-OFF
Dual
Legend Color
Black
White
Black
Red
Green
Blue
Yellow
Gray
Orange
B
D
G
J
1
2
3
4
5
6
7
8
K
N
O
1
Curved Rocker, Single Color, Horizontal Legend
White
Curved Rocker, Push To Reset, Two Color Visi, Vertical Legend
Curved Rocker, Push To Reset, Two Color Visi, Horizontal Legend
Flat Rocker, Two Color Visi, Vertical Legend
White
White
L
White
2
Flat Rocker, Two Color Visi, Horizontal Legend
N
Q
S
Black
3
Flat Rocker, Single Color, Vertical Legend
Black
4
Flat Rocker, Single Color, Horizontal Legend
Black
5
Flat Rocker, Push To Reset, Two Color Visi, Vertical Legend
Flat Rocker, Push To Reset, Two Color Visi, Horizontal Legend
Flat Rocker, Push To Reset, Single Color, Vertical Legend
Flat Rocker, Push To Reset, Single Color, Horizontal Legend
6
10 MOUNTING
7
ROCKER / MOUNTING INSERT STYLE
Standard Rocker Bezel - 6-32 Inserts
Standard Rocker Bezel - M3 Inserts
Rocker Guard Bezel - 6-32 Inserts
Rocker Guard Bezel - M3 Inserts
8
A
B
C
D
E
F
2
3 POLES
One
1
2
Two
3
Three
Standard Bezel with recessed Off Side Flat Rocker - 6-32 Inserts
Standard Bezel with recessed Off Side Flat Rocker - M3 Inserts
Push to Reset Bezel - 6-32 Inserts
4 CIRCUIT
Series Trip (parallel pole)
G
H
P
Push to Reset Bezel - M3 Inserts
11 MAXIMUM APPLICATION RATING
80 DC
5 AUXILIARY/ALARM SWITCH
M
0
2
3
4
without Aux Switch
6
7
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C
Term. (Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
4
8
9
12 AGENCY APPROVAL
A
G
J
Without Approval
5
S.P.S.T., N.O., 0.110 Q.C
Term. (Gold Contacts)
UL489 Listed
UL489A Listed, TUV Certified
UL489A Listed
T
7
UL489A Listed, TUV Certified
6 FREQUENCY & DELAY
D1 DC Ultra Short
D2 DC Short
D4 DC Medium
D6 DC Long
Notes:
1
Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line
and Load Terminals. For Terminal Code A, Line and Load Terminals must be
connected to a copper bus bar having a minimum cross-section of 0.078 square
inches. Terminal Code A is not available on the single pole unit.
Ratings for 101 to 125 amps are available in 1-pole.
2
Ratings from 110 to 200 amps are available in 2-pole.
For ratings from 225-300 amps, specify 3-pole.
1 pole only available with terminal codes 3 and 6.
Agency codes K and 7 are not available with 1 pole.
Agency code J is only available with 1 pole.
Agency code G is only available in 2 and 3 pole.
Circuit P, ratings 101-150 amps (2 pole) and ratings 151-250 amps (3 pole).
2
7 CURRENT RATING (AMPERES)
CODE AMPERES
3
4
810 100.00
811 110.00
812 120.00
912 125.00
813 130.00
814 140.00
815 150.00
816 160.00
817 170.00
917 175.00
818 180.00
819 190.00
820 200.00
922 225.00
825 250.00
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
19
C-Series Circuit Breaker - Rocker UL Listed – Ordering Scheme
C C 3 B 0 14 450 1 2 A K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
4
7 CURRENT RATING (AMPERES)
1 SERIES
C
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.00
1
2 ACTUATOR
Two Color Visi-Rocker
Single color
C
D
F
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate OFF, vertical legend
J
Vertical legend
K
Horizontal legend
G
Indicate OFF, horizontal legend
ROCKER STYLE DESCRIPTIONS
INDICATE "ON"
INDICATE "OFF"
CODE "F"
SINGLE COLOR
CODE "J"
CODE "C"
LINE
INDICATE
COLOR
LINE
LINE
LOCATION
CODE "D"
CODE "G"
CODE "K"
8 TERMINAL
5
7
1
2
Stud 10-32
6
Stud M6
6
7,8
7,8
6,8
Screw 10-32 with saddle
& washer clamps
Stud 1/4-20
9
7/16” Clip Terminal
Plug-In Stud
A
C
7
6
6
3
4
5
5/16” Clip Terminal
LINE
LINE
LINE
Stud M5 x 0.8
Screw M5 x 0.8 with saddle
& washer clamps
1
3 POLES
One
1
2
Two
3
Three
11
9 ACTUATOR COLOR & LEGEND
Actuator or
4 CIRCUIT
Series Trip (current)
Visi-Color
Marking:
Marking Color:
Single Color
Rocker/Handle
Black
B
10
Color:
White
Black
Red
ON-OFF Dual
Visi-Rocker
White
n/a
B
D
G
J
1
2
3
4
5
6
7
8
2
5 AUXILIARY / ALARM SWITCH
White
0
2
3
4
without Aux Switch
White
Red
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
Green
Blue
White
Green
Blue
L
White
Yellow
Gray
Orange
N
Q
S
Black
Yellow
Gray
Black
Black
Orange
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
8
8
8
8
12
42 50/60Hz Short, High-inrush
10 MOUNTING / BARRIERS
Standard Rocker Bezel
13
44 50/60Hz Medium, High-inrush
BARRIERS
14 DC Medium
46 50/60Hz Long, High-inrush
Threaded Insert, 2 per pole
6-32 X 0.195 inches
ISO M3 x 5mm
Rockerguard Bezel
Threaded Insert, 2 per pole
6-32 x 0.195 inches
ISO M3 x 5mm
16 DC Long
52 DC Short, High-inrush
A
C
yes
yes
8
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
54 DC Medium, High-inrush
56 DC Long, High-inrush
B
D
yes
yes
Notes:
1
Multi-pole breakers have all breakers identical except when specifying Auxiliary
switch and/or mixed poles, and have one rocker per breaker.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right
pole.
11 MAXIMUM APPLICATION RATING
2
B
C
D
F
125 DC
120/240 AC
240 AC
277 AC
120 AC
80 DC
14
3
4
5
6
7
8
9
Available up to 50 amps maximum.
Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.
Terminal Code 1 available to 60 amps maximum.
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
Terminal Codes 3, 6, 9 & A available to 100 amps maximum.
Terminal Codes 9 & C are not VDE approved.
K
M
Color shown is visi and legend with remainder of rocker black
12 AGENCY APPROVAL
10 Dual = ON-OFF/I-O legend on actuator.
11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker.
12 Rockerguard available with all actuator codes.
13 Barriers supplied on multi-pole units only.
14 2 & 3 pole circuit breakers required for 120/240 AC rating.
A
F
G
J
without approvals
UL 489 Listed, CSA Certified, & VDE Certified
UL 489 Listed & CSA Certified
UL489 Listed, CSA Certified & TUV Certified
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
20
C-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Schematic shown represents current trip circuit.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
21
C-Series Circuit Breaker - Rocker – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
4
Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON.
For pole orientation with horizontal legend, rotate front view clockwise 90°.
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
22
C-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme
C 1 2 B 0 10 450 1 2 1 E
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
9
1 SERIES
C
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
1
2 ACTUATOR
Two Color Visi-Rocker
1
Indicate OFF,
vertical legend
Indicate OFF,
horizontal legend
2
Single color
3
4
Vertical legend
Horizontal legend
Push-To-Reset, Visi-Rocker
5
Indicate OFF,
vertical legend
Indicate OFF,
9
660 60.000
9
670 70.000
6
9
680 80.000
horizontal legend
9
685 85.000
Push-To-Reset , Single color
9
690 90.000
7
8
Vertical legend
9
695 95.000
Horizontal legend
9
810 100.00
7
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
2
3 POLES
One
CODE AMPERES
1
2
Two
3
Three
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
4
4
4,5
4,5
4 CIRCUIT
F
Relay Trip (Current)
J06
6 AC
3
A
B
C
D
E
Switch Only (No Coil)
G
H
Relay Trip (Voltage)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
8 TERMINAL
4
4
K
Dual Coil with Relay Trip
Voltage Coil
10
12
1
2
3
4
5
Stud 10-32
6
Stud M6
11
12
11
11
13
15
14
15
Screw 10-32
Stud 1/4-20
7
0.250 Double Quick Connect
7/16” Clip Terminal
Plug-In Stud
9
Stud M5 x 0.8
Screw M5 x 0.8
A
C
6
5 AUXILIARY / ALARM SWITCH
5/16” Clip Terminal
0
2
3
4
without Aux Switch
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
16,17,18
9 ACTUATOR COLOR & LEGEND
Actuator or
Visi-Color Marking:
MarkingColor:
Single Color
Color:
White
Black
Red
I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker
A
C
F
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
30 DC 50/60Hz Instantaneous
31 DC 50/60Hz Ultra Short
32 DC 50/60Hz Short
7
Red
10 DC Instantaneous
Green
Blue
H
K
M
P
R
Green
Blue
11 DC Ultra Short
12 DC Short
L
34 DC 50/60Hz Medium
36 DC 50/60Hz Long
Yellow
Gray
N
Q
S
Yellow
Gray
Orange
14 DC Medium
16 DC Long
8
8
8
8
8
8
42 50/60Hz Short, High-inrush
7
Orange
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
52 DC Short, High-inrush
1
10 MOUNTING / BARRIERS
54 DC Medium, High-inrush
STANDARD ROCKER BEZEL
6-32 x 0.195 inches
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
BARRIERS
VOLTAGE
<300
56 DC Long, High-inrush
1
2
3
4
5
6
no
yes
yes
no
<300
Notes:
19
19
≥300
1
2
Push-to-reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all poles identical except when specifying Auxiliary switch
and/or mixed poles, and have one rocker per breaker. Rocker location as viewed
from front panel: 2 pole – left pole; 3 pole – center pole.
<300
ISO M3 x 5mm
yes
yes
<300
ISO M3 x 5mm
≥300
3
Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30
amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For
55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810.
Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit
Codes D,F,H & K available up to 50 amps maximum Current Rating.
Consult factory for available Dual Coil options, as special catalog number is required.
Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line
voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously
and are rated for intermittent duty only.
RECESSED OFF ROCKER
6-32 x 0.195 inches
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
7
no
<300
<300
≥300
<300
<300
≥300
8
yes
yes
no
4
5
9
A
C
E
ISO M3 x 5mm
yes
yes
ISO M3 x 5mm
PUSH-TO-RESET BEZEL
6-32 x 0.195 inches
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
6
Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole
breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxilary
switch codes 2, 3 & 4 are VDE approved.
B
D
F
no
<300
<300
≥300
<300
<300
≥300
yes
yes
no
19
19
7
8
9
Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
Available with Circuit Codes B & D only, and up to 50 amps maximum.
Current ratings 60-70 are available up to four poles maximum. Current ratings 71 -
100 are available up to two poles maximum.
H
J
ISO M3 x 5mm
yes
yes
M
ISO M3 x 5mm
10 Terminal Code 1 available to 60 amps maximum.
11 Terminal Codes 2,4,5 & C available to 50 amps maximum.
12 Terminal Codes 3,6 & 9 available to 100 amps maximum.
13 Terminal Code 7 available to 25 amps maximum.
11 AGENCY APPROVAL
14 Terminal Code A available to 100 amps maximum.
C
E
I
UL Recognized & CSA Accepted
15 Terminal Codes 7, 9 & C are not VDE approved.
TUV Certified, UL Recognized & CSA Accepted
16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 &
8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator
codes 5 & 6.
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
UL489 Construction: UL Recognized & CSA Accepted
UL489 Construction: TUV Certified, UL Recognized & CSA Accepted
L
R
18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker.
19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and
limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be
used in applications with a motor.
20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are
available in ink stamping only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
23
C-Series Circuit Breaker - Flat Rocker UL489 Listed – Ordering Scheme
C 1 2 B 0 14 450 1 2 A K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
5
7 CURRENT RATING (AMPERES)
1 SERIES
C
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.00
1
2 ACTUATOR
Two Color Visi-Rocker
Push-To-Reset, Visi-Rocker
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Single color
Push-To-Reset , Single color
3
4
Vertical legend
Horizontal legend
7
8
Vertical legend
Horizontal legend
8 TERMINAL
6
8
8,9
8
1
2
3
4
5
Stud 10-32
6
Stud M6
7
8
7
7
Screw 10-32
Stud 1/4-20
Stud M5 x 0.8
9
7/16” Clip Terminal
Plug-In Stud
A
C
7,9
5/16” Clip Terminal
Screw M5 x 0.8
10
9 ACTUATOR COLOR & LEGEND
2
3 POLES
One
Actuator or
1
2
Two
3
Three
Visi-Color
Marking:
Marking Color:
Single Color
Rocker/Handle
Black
11,12
Color:
White
Black
Red
ON-OFF Dual
Visi-Rocker
White
n/a
4 CIRCUIT
Series Trip (current)
B
D
G
J
1
2
3
4
5
6
7
8
B
White
White
Red
Green
Blue
White
Green
Blue
3
5 AUXILIARY / ALARM SWITCH
L
White
Yellow
Gray
Orange
N
Q
S
Black
Yellow
Gray
0
2
3
4
without Aux Switch
Black
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
Black
Orange
10 MOUNTING / BARRIERS
15
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
6-32 X 0.195 inches
BARRIERS
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
4
4
4
4
4
4
A
C
yes
yes
42 50/60Hz Short, High-inrush
ISO M3 x 5mm
44 50/60Hz Medium, High-inrush
14
RECESSED OFF ROCKER
46 50/60Hz Long, High-inrush
Threaded Insert, 2 per pole
6-32 x 0.195 inches
ISO M3 x 5mm
52 DC Short, High-inrush
E
F
yes
yes
54 DC Medium, High-inrush
56 DC Long, High-inrush
13
PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
ISO M3 x 5mm
B
D
yes
yes
Notes:
1
2
Push-to-reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary
switch and/or mixed poles, and have one rocker per breaker.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme
right pole.
11 MAXIMUM APPLICATION RATING
3
B
C
D
F
K
M
125 DC
120/240 AC
240 AC
277 AC
120 AC
80 DC
16
4
5
6
7
8
9
Available up to 50 amps maximum.
Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.
Terminal Code 1 available to 60 amps maximum.
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
Terminal Codes 3, 6, 9 & A available to 100 amps maximum.
Terminal Codes 9 & C are not VDE approved.
10 Color shown is visi and legend with remainder of rocker black
11 Dual = ON-OFF/I-O legend on actuator.
12 TUV approval requires Dual (I-O, ON-OFF) markings on rocker.
13 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered.
Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator
codes 5 & 6.
12
12 AGENCY APPROVAL
A
G
J
without approvals
UL 489 Listed & CSA Certified
UL489 Listed, CSA Certified & TUV Certified
14 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker
are available in ink stamping only.
15 Barriers supplied on multi-pole units only.
16 2 & 3 pole circuit breakers required for 120/240 AC rating.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
24
C-Series Circuit Breaker - Flat Rocker – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
For pole orientation with horizontal legend, rotate front view clockwise 90°.
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
25
Sales Representatives, Distributors & Company Profile
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_01_2019